To conclude, the positive impact of the implementation of passive design strategies rises the comfort hours in-use period in the open plan office a 70% and in the individual office a 55% and a decrease of 60% of primary energy demand. Results from the net energy balance in the base model present a primary energy demand of 116 kWh/m 2/year and the optimization model of 55 kWh/m 2/year. For all orientations tested, multiple horizontal overhangs have better performance than vertical ones. ![]() Two office configurations were discussed, open plan and individual office, both options with a high trend to overheat. On-site measurements were taken to collect hygrothermal data and energy demand information. ![]() The building design integrates an efficient envelope and renewable energy generation from photovoltaic solar panels on-grid. The objective is to assess their effectiveness with zero-energy building criteria. This paper presents an optimization of the performance of an office building with a mixed-mode run, including night ventilative cooling and shading strategies in summer. Passive energy-efficient design in temperate climates with clear-sky conditions and high solar radiation can lead to a significant reduction in energy use while promoting occupant comfort. Journal of Verification, Validation and Uncertainty Quantification.Journal of Thermal Science and Engineering Applications.Journal of Offshore Mechanics and Arctic Engineering.Journal of Nuclear Engineering and Radiation Science.Journal of Nondestructive Evaluation, Diagnostics and Prognostics of Engineering Systems.Journal of Nanotechnology in Engineering and Medicine.Journal of Micro and Nano-Manufacturing.Journal of Manufacturing Science and Engineering.Journal of Engineering Materials and Technology.Journal of Engineering for Sustainable Buildings and Cities.Journal of Engineering for Gas Turbines and Power.Journal of Engineering and Science in Medical Diagnostics and Therapy.Journal of Electrochemical Energy Conversion and Storage.Slightly positive air pressure (More balanced) How to configure the fans. Journal of Dynamic Systems, Measurement, and Control The main three types of case air pressure.Journal of Computing and Information Science in Engineering.Journal of Computational and Nonlinear Dynamics.Journal of Autonomous Vehicles and Systems.ASME Letters in Dynamic Systems and Control.ASCE-ASME Journal of Risk and Uncertainty in Engineering Systems, Part B: Mechanical Engineering. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |